Miniature ±60 g Quartz Accelerometer for Harsh Environments
Quartz Flexure Accelerometer · BJGM18T01
Miniature quartz flexure accelerometer with ±60 g input range and ≥300 Hz bandwidth in a hermetically sealed stainless-steel package under 30 g. Analog current output for acceleration and temperature, bias temperature sensitivity ≤50 µg/°C, qualified to MIL-STD-810G for vibration, shock, humidity, and explosive atmospheres.
- Performance SpecificationsInput Range
- ±60 g
- Performance SpecificationsBias Error
- ≤4 mg
- Performance SpecificationsBandwidth
- ≥300 Hz
Confirm configuration, interfaces and documentation with your inquiry.
The BJGM18T01 is a high-performance inertial sensor optimized for compact aerospace, defense, and industrial applications. Engineered in a stainless-steel hermetic package, it delivers mission-ready reliability with high shock tolerance and thermal stability.
Its compact design and robust performance make it ideal for space-constrained applications requiring high precision and durability. Key Features
- ±60 g dynamic range with high bandwidth
- High stability under thermal and mechanical stress
- Compact stainless steel construction (< 30 g)
- Analog current output for acceleration and temperature
- No recalibration required over lifetime
- MIL-STD-810G compliant for vibration, shock, humidity, and EMI immunity
- Hermetically sealed and fungus resistant
Applications
Technical Specifications
Performance Specifications
- Input Range
- ±60 g
- Bias Error
- ≤4 mg
- Bias Long-Term Repeatability (1 year)
- ≤1 (3σ) mg
- Bias Temperature Sensitivity
- ≤50 µg/°C
- Residual Bias Modeling Error
- ≤170 (1σ) µg
- Scale Factor
- 0.65 to 0.85 mA/g
- Scale Factor Long-Term Repeatability (1 year)
- ≤600 (3σ) ppm
- Scale Factor Temperature Sensitivity
- ≤100 ppm/°C
- Residual Scale Factor Modeling Error
- ≤225 (1σ) ppm
- Scale Factor Non-Linearity
- ≤30 µg/g²
- Vibration Rectification Error (50–200 Hz)
- ≤25 µg/g²rms
- Vibration Rectification Error (200–750 Hz)
- ≤50 µg/g²rms
- Vibration Rectification Error (750–2000 Hz)
- ≤100 µg/g²rms
- Intrinsic Noise
- ≤7 (0–10 Hz), ≤70 (10–500 Hz), ≤1500 (500–10k Hz) µgrms
- Resolution / Threshold
- ≤1 µg
- Bandwidth
- ≥300 Hz
Environmental Specifications
- Operating Temperature
- -55°C to +95°C
- Storage Temperature
- -55°C to +95°C
- Maximum Temperature Rate
- < 5°C/min
- Random Vibration (non-operating)
- 6grms, 0.0185 g²/Hz, 5–2000 Hz, 60 min/axis
- Random Vibration (operating)
- 14grms, 0.0985 g²/Hz, 5–2000 Hz, 3 min/axis
- Sine Vibration
- 15g peak, 20–2000 Hz, 2 min/decade sweep/axis
- Shock Tolerance
- 40g, 11 ms, each orthogonal axis (MIL-STD-810G)
- Magnetic Immunity
- ≤10 Gauss, no permanent bias shift
- Hermetic Sealing
- Yes, for full humidity & thermal range endurance
- Fungus Resistance
- Compliant with MIL-STD-810G, Method 508.6
- Explosive Atmosphere Compatibility
- Compliant with MIL-STD-810G, Method 511.5, does not ignite air mixture
Electrical Specifications
- Input Voltage Range
- ±13 to ±16 VDC
- Nominal Voltage
- ±15 VDC
- Quiescent Current (per supply)
- < 20 mA
- Quiescent Power (@ ±15 VDC)
- < 600 mW
- Full Scale Max Current
- < 100 mA
- Output Type
- Analog current (Accel & Temp)
- [1]Bias long-term repeatability is a 1-year 3σ figure; residual bias and scale-factor modeling errors are 1σ values after thermal modeling.
- [2]Vibration rectification error is specified in three bands — 50–200 Hz, 200–750 Hz, and 750–2000 Hz.
- [3]Intrinsic noise is specified over 0–10 Hz, 10–500 Hz, and 500 Hz–10 kHz bands.
Package Information
Technical Drawings



Frequently Asked Questions
What is BJGM18T01?+−
Miniature quartz flexure accelerometer with ±60 g input range and ≥300 Hz bandwidth in a hermetically sealed stainless-steel package under 30 g. Analog current output for acceleration and temperature, bias temperature sensitivity ≤50 µg/°C, qualified to MIL-STD-810G for vibration, shock, humidity, and explosive atmospheres.
Which specifications are published for BJGM18T01?+−
Performance Specifications — Input Range: ±60 g; Performance Specifications — Bias Error: ≤4 mg; Performance Specifications — Bias Long-Term Repeatability (1 year): ≤1 (3σ) mg. Measurement conditions: Bias long-term repeatability is a 1-year 3σ figure; residual bias and scale-factor modeling errors are 1σ values after thermal modeling. Vibration rectification error is specified in three bands — 50–200 Hz, 200–750 Hz, and 750–2000 Hz. Intrinsic noise is specified over 0–10 Hz, 10–500 Hz, and 500 Hz–10 kHz bands. See the technical specifications for the complete parameter list.
Related Products
Navigation / QAC
Navigation-Grade Quartz Flexure Accelerometer (±60 g)
BJGM25A01
- Primary Performance SpecificationsInput Range
- ±60 g
- Primary Performance SpecificationsBandwidth
- >300 Hz
Navigation / QAC
Navigation-Grade Quartz Accelerometer (±60 g)
BJGM25N01
- Performance SpecificationsInput Range
- ±60 g
- Performance SpecificationsBias Error
- ≤ 4 mg
Navigation / QAC
Miniature Quartz Flexure Accelerometer (±60 g, Ø18.2 mm)
JDSJ18TK01
- General SpecificationsRange
- ±60g
- Physical and Environmental SpecificationsBandwidth
- 800–2500 Hz