HXG46JD090
Standard-precision fiber optic sensing coils with fine-diameter fiber design and UV-cured coating for fiber optic gyroscope applications
Inner Diameter
21.0±0.1 mm
Outer Diameter
≤33.0 mm
Mean Diameter
28.0±0.5 mm
The standard-precision fiber optic coil is manufactured using fine-diameter fiber and UV-cured coating technology, integrating 20 years of research and production experience. This coil provides a reliable sensing solution for fiber optic gyroscopes with moderate precision requirements.
Key Features
- High reliability
- Batch consistency
- Excellent temperature and vibration performance
Applications
Technical Specifications
Geometry Parameters
Inner Diameter
21.0±0.1
mmOuter Diameter
≤33.0
mmMean Diameter
28.0±0.5
mmHeight
15.0±0.1
mmOptical Parameters
Fiber Length
230±10
mAttenuation Coefficient
≤-1.0
dB/kmCrosstalk (Normal Temp.)
≤-18
dBCrosstalk (Full Temp.)
≤-16
dBPerformance Parameters
Bias
≤3
°/hThermal Drift
≤4
°/hMagnetic Drift
≤3
°/h/GScale Factor Stability (Normal Temp.)
≤100
ppmScale Factor Stability (Full Temp.)
≤3000
ppmRandom Walk Coefficient
≤0.06
°/√hEnvironmental Parameters
Operating Temperature
-45~+80
°CMTTF
≥40
Yr.Geometry Parameters
Inner Diameter
50.0±0.1
mmOuter Diameter
≤60.0
mmMean Diameter
55.0±0.5
mmHeight
20.0±0.1
mmOptical Parameters
Fiber Length
500±10
mAttenuation Coefficient
≤-0.8
dB/kmCrosstalk (Normal Temp.)
≤-28
dBCrosstalk (Full Temp.)
≤-22
dBPerformance Parameters
Bias
≤2
°/hThermal Drift
≤3
°/hMagnetic Drift
≤2
°/h/GScale Factor Stability (Normal Temp.)
≤80
ppmScale Factor Stability (Full Temp.)
≤2400
ppmRandom Walk Coefficient
≤0.03
°/√hEnvironmental Parameters
Operating Temperature
-45~+80
°CMTTF
≥30
Yr.Geometry Parameters
Inner Diameter
70.0±0.1
mmOuter Diameter
≤90.0
mmMean Diameter
80.0±0.5
mmHeight
25.0±0.1
mmOptical Parameters
Fiber Length
800±10
mAttenuation Coefficient
≤-0.8
dB/kmCrosstalk (Normal Temp.)
≤-26
dBCrosstalk (Full Temp.)
≤-21
dBPerformance Parameters
Bias
≤1.5
°/hThermal Drift
≤2
°/hMagnetic Drift
≤1.5
°/h/GScale Factor Stability (Normal Temp.)
≤50
ppmScale Factor Stability (Full Temp.)
≤2000
ppmRandom Walk Coefficient
≤0.01
°/√hEnvironmental Parameters
Operating Temperature
-45~+80
°CMTTF
≥30
Yr.